glam/schemas/20251121/linkml/modules/classes/ClimateControl.yaml
kempersc 1516d509cf Add metadata to LinkML class definitions and update prefixes
- Added `id`, `name`, `title`, and `description` fields to multiple LinkML class YAML files.
- Standardized prefixes across all class definitions.
- Introduced a new script `fix_linkml_metadata.py` to automate the addition of metadata to class files.
- Updated existing class files to ensure compliance with the new metadata structure.
2026-01-29 17:40:47 +01:00

171 lines
5.7 KiB
YAML

id: https://nde.nl/ontology/hc/class/ClimateControl
name: ClimateControl
title: Climate Control
description: LinkML class definition for Climate Control
prefixes:
linkml: https://w3id.org/linkml/
schema: http://schema.org/
skos: http://www.w3.org/2004/02/skos/core#
rico: https://www.ica.org/standards/RiC/ontology#
wd: http://www.wikidata.org/entity/
# ClimateControl class
# Climate control system or approach for heritage facilities
#
# Generation date: 2026-01-19
# Rule compliance: 53 (slot_fixes.yaml), 39 (RiC-O naming), 0b (Type/Types pattern)
#
# Created for climate_control_type migration
id: https://nde.nl/ontology/hc/class/climate_control
name: climate_control_class
title: Climate Control Class
prefixes:
linkml: https://w3id.org/linkml/
hc: https://nde.nl/ontology/hc/
schema: http://schema.org/
crm: http://www.cidoc-crm.org/cidoc-crm/
aat: http://vocab.getty.edu/aat/
default_prefix: hc
imports:
- linkml:types
- ../slots/has_or_had_label
- ../slots/has_or_had_description
- ../slots/has_or_had_type
- ./ClimateControlType
classes:
ClimateControl:
class_uri: aat:300264752
description: |
Climate control system or approach for managing environmental conditions.
**DEFINITION**:
A ClimateControl represents the physical system, equipment, or approach
used to manage temperature, humidity, air quality, and other environmental
factors in heritage facilities.
**GETTY AAT ALIGNMENT**:
`aat:300264752` (climate control systems) - "Systems for controlling
environmental conditions such as temperature and humidity."
**USE CASES**:
1. **Full HVAC System**:
```yaml
ClimateControl:
has_or_had_label: "Main Gallery HVAC"
has_or_had_type: HVAC
has_or_had_description:
description_text: "Central HVAC with 24/7 monitoring, backup power"
```
2. **Basic Heating**:
```yaml
ClimateControl:
has_or_had_label: "Warehouse Heating"
has_or_had_type: HEATED
```
3. **Dehumidification Only**:
```yaml
ClimateControl:
has_or_had_label: "Photo Archive Dehumidifier"
has_or_had_type: DEHUMIDIFIED
```
**RELATIONSHIP TO ClimateControlType**:
```
ClimateControl
└── has_or_had_type ──► ClimateControlType
└── (HEATED, HVAC, DEHUMIDIFIED, NONE, etc.)
```
exact_mappings:
- aat:300264752
close_mappings:
- schema:Product
related_mappings:
- crm:E22_Human-Made_Object
slots:
- has_or_had_label
- has_or_had_description
- has_or_had_type
slot_usage:
has_or_had_label:
description: |
Name or identifier for this climate control system.
range: string
required: false
examples:
- value: "Main Stack HVAC System"
description: Named HVAC system
- value: "Depot B Climate Control"
description: Named by location
has_or_had_description:
description: |
Description of the climate control system capabilities.
examples:
- value:
description_text: "Precision HVAC with temperature control ±1°C, humidity control ±3% RH. Redundant systems with automatic failover."
description_type: technical
description: Detailed technical description
has_or_had_type:
range: ClimateControlType
required: true
description: |
Type of climate control (HEATED, HVAC, DEHUMIDIFIED, NONE, etc.).
examples:
- value: HVAC
description: Full heating/cooling system
- value: HEATED
description: Heating only
- value: DEHUMIDIFIED
description: Humidity control only
- value: NONE
description: No climate control
annotations:
custodian_types: '["*"]'
custodian_types_rationale: Climate control applies to all heritage custodian types with physical facilities.
custodian_types_primary: A
specificity_score: 0.55
specificity_rationale: Moderately specific - common across facility management contexts.
replaces_slots: "climate_control_type (partial - represents the system, type is separate)"
comments:
- "Represents climate control systems/equipment"
- "Maps to Getty AAT 300264752"
- "Type classification via has_or_had_type → ClimateControlType"
examples:
- value:
has_or_had_label: "Rijksmuseum Collection Storage HVAC"
has_or_had_type: HVAC
has_or_had_description:
description_text: "Precision climate control with T=20±1°C, RH=50±3%. Redundant compressors, backup power, 24/7 monitoring."
description_type: technical
description: Museum collection storage climate system
- value:
has_or_had_label: "Logistics Warehouse Heating"
has_or_had_type: HEATED
has_or_had_description:
description_text: "Basic gas heating to prevent freezing. No humidity control."
description_type: technical
description: Basic warehouse heating
- value:
has_or_had_label: "Photo Archive Dehumidifier"
has_or_had_type: DEHUMIDIFIED
has_or_had_description:
description_text: "Portable dehumidifier maintaining RH below 50%."
description_type: technical
description: Dehumidification for photos