- Removed obsolete slots: `has_or_had_custodian_observation`, `provider`, and `specificity_annotation`. - Updated `has_or_had_score` slot to use `SpecificityScore` class and modified its description and examples. - Added new slots: `end_seconds`, `end_time`, `has_archive_path`, `has_or_had_custodian_name`, `protocol_name`, and `protocol_version`. - Introduced a script `check_annotation_types.py` to validate the presence and structure of `custodian_types` in YAML files. - Added a script `update_specificity.py` to automate updates related to `SpecificityAnnotation` to `SpecificityScore`.
226 lines
8.8 KiB
YAML
226 lines
8.8 KiB
YAML
id: https://nde.nl/ontology/hc/class/EnvironmentalZone
|
|
name: environmental_zone_class
|
|
title: Environmental Zone Class
|
|
prefixes:
|
|
linkml: https://w3id.org/linkml/
|
|
hc: https://nde.nl/ontology/hc/
|
|
crm: http://www.cidoc-crm.org/cidoc-crm/
|
|
sosa: http://www.w3.org/ns/sosa/
|
|
schema: http://schema.org/
|
|
dcterms: http://purl.org/dc/terms/
|
|
wd: http://www.wikidata.org/entity/
|
|
aat: http://vocab.getty.edu/aat/
|
|
default_prefix: hc
|
|
imports:
|
|
- linkml:types
|
|
- ../enums/MeasureUnitEnum
|
|
- ../enums/SetpointTypeEnum
|
|
- ../slots/allows_or_allowed
|
|
- ../slots/contains_or_contained_contains_unit
|
|
- ../slots/has_or_had_description
|
|
- ../slots/has_or_had_identifier
|
|
- ../slots/has_or_had_label
|
|
- ../slots/has_or_had_requirement
|
|
- ../slots/has_or_had_score
|
|
- ../slots/has_or_had_setpoint
|
|
- ../slots/has_or_had_tolerance
|
|
- ../slots/has_or_had_type
|
|
- ../slots/max_annual_light_exposure
|
|
- ../slots/max_light_lux
|
|
- ../slots/monitoring_platform
|
|
- ../slots/monitoring_platform_url
|
|
- ../slots/observation
|
|
- ../slots/part_of_facility
|
|
- ../slots/temporal_extent
|
|
classes:
|
|
EnvironmentalZone:
|
|
class_uri: hc:EnvironmentalZone
|
|
description: 'A climate-controlled area within a storage facility with specific environmental parameters (temperature, relative humidity, light levels, air quality).
|
|
DEFINITION: An EnvironmentalZone represents a physically distinct area within a storage facility that maintains specific environmental conditions. Different collection types require different zones based on their material composition and preservation requirements.
|
|
Examples include climate-controlled archive rooms (18C, 50% RH), cold storage vaults for film (-5C to +4C), photographic materials storage (15C, 35% RH), textile storage (stable RH, low light), and general collection storage (ambient controlled).
|
|
Wikidata Alignment: Q1759899 (climate control).
|
|
HC Ontology Extension (hc-storage.ttl): Primary class hc:EnvironmentalZone (subclass of crm:E27_Site). Provides environmental preset instances including hc:StandardArchiveEnvironment (18C, 50% RH, 50 lux), hc:PhotographicMaterialsEnvironment (15C, 35% RH), hc:ColdStorageEnvironment (-5C, 30% RH), hc:TextileStorageEnvironment (18C, 50% RH, 15000 lux-hours/year).
|
|
Key HC properties: hc:hasStorageSection (links zone to storage units), hc:hasEnvironmentalRequirement (links to climate specs), hc:meetsRequirement (indicates compliance), hc:hasEnvironmentalObservation (links to sensor readings), hc:monitoredByPlatform (links to sensor systems).
|
|
SOSA/SSN Integration: Environmental zones can be monitored using sensor networks where Zone is a sosa:FeatureOfInterest, Observations are hc:StorageEnvironmentObservation, and Sensors are hosted on hc:EnvironmentalSensorPlatform.
|
|
CIDOC-CRM Alignment (v7.1.3): Base class crm:E27_Site - Zones are physical locations. StorageFacility has_section EnvironmentalZone which has_section StorageUnit.'
|
|
exact_mappings:
|
|
- hc:EnvironmentalZone
|
|
- crm:E27_Site
|
|
close_mappings:
|
|
- aat:300265612
|
|
- wikidata:Q1759899
|
|
related_mappings:
|
|
- hc:StorageFacility
|
|
- hc:StorageUnit
|
|
- hc:EnvironmentalRequirement
|
|
- sosa:FeatureOfInterest
|
|
slots:
|
|
- contains_or_contained_contains_unit
|
|
- has_or_had_tolerance
|
|
- allows_or_allowed
|
|
- max_annual_light_exposure
|
|
- max_light_lux
|
|
- monitoring_platform
|
|
- monitoring_platform_url
|
|
- observation
|
|
- part_of_facility
|
|
- has_or_had_setpoint
|
|
- has_or_had_score
|
|
- temporal_extent
|
|
- has_or_had_description
|
|
- has_or_had_identifier
|
|
- has_or_had_label
|
|
- has_or_had_type
|
|
slot_usage:
|
|
has_or_had_identifier:
|
|
range: uriorcurie
|
|
required: true
|
|
identifier: true
|
|
examples:
|
|
- value: https://nde.nl/ontology/hc/zone/na-depot-a-standard
|
|
has_or_had_label:
|
|
range: string
|
|
required: true
|
|
examples:
|
|
- value: Standard Archive Storage Zone A
|
|
- value: Cold Storage Vault - Film Negatives
|
|
- value: Photographic Materials Room
|
|
has_or_had_type:
|
|
range: uriorcurie
|
|
required: true
|
|
examples:
|
|
- value: ARCHIVE_STANDARD
|
|
- value: COLD_STORAGE
|
|
- value: PHOTOGRAPHIC
|
|
has_or_had_description:
|
|
range: string
|
|
has_or_had_setpoint:
|
|
range: Setpoint
|
|
multivalued: true
|
|
inlined: true
|
|
inlined_as_list: true
|
|
examples:
|
|
- value:
|
|
- setpoint_type: TEMPERATURE
|
|
setpoint_value: 18.0
|
|
setpoint_min: 16.0
|
|
setpoint_max: 20.0
|
|
setpoint_tolerance: 2.0
|
|
setpoint_unit: DEGREE_CELSIUS
|
|
- setpoint_type: RELATIVE_HUMIDITY
|
|
setpoint_value: 50.0
|
|
setpoint_min: 45.0
|
|
setpoint_max: 55.0
|
|
setpoint_tolerance: 5.0
|
|
setpoint_unit: PERCENT
|
|
allows_or_allowed:
|
|
range: string
|
|
multivalued: true
|
|
inlined: true
|
|
inlined_as_list: true
|
|
examples:
|
|
- value:
|
|
- deviation_value: 2.0
|
|
has_or_had_measurement_unit:
|
|
has_or_had_type: DEGREE_CELSIUS
|
|
has_or_had_symbol: "\xB0C"
|
|
iso_standard_reference: ISO 11799:2015
|
|
- value:
|
|
- deviation_value: 3.0
|
|
iso_standard_reference: ISO 18911:2010
|
|
has_or_had_tolerance:
|
|
range: float
|
|
examples:
|
|
- value: 5.0
|
|
max_light_lux:
|
|
range: float
|
|
examples:
|
|
- value: 50.0
|
|
- value: 0.0
|
|
max_annual_light_exposure:
|
|
range: float
|
|
examples:
|
|
- value: 15000.0
|
|
observation:
|
|
range: StorageCondition
|
|
multivalued: true
|
|
inlined_as_list: true
|
|
monitoring_platform:
|
|
range: string
|
|
examples:
|
|
- value: Hanwell RadioLog environmental monitoring system
|
|
- value: Meaco Climate Manager
|
|
monitoring_platform_url:
|
|
range: uri
|
|
part_of_facility:
|
|
range: Storage
|
|
required: true
|
|
contains_or_contained_contains_unit:
|
|
range: StorageUnit
|
|
multivalued: true
|
|
inlined_as_list: true
|
|
temporal_extent:
|
|
range: TimeSpan
|
|
inlined: true
|
|
required: false
|
|
comments:
|
|
- EnvironmentalZone sits between Storage (facility) and StorageUnit (compartment)
|
|
- Environmental parameters should align with material preservation standards
|
|
- SOSA integration enables IoT sensor data ingestion
|
|
- HC ontology provides preset environmental requirements for common scenarios
|
|
see_also:
|
|
- https://nde.nl/ontology/hc/EnvironmentalZone
|
|
- http://vocab.getty.edu/aat/300265612
|
|
- http://www.w3.org/ns/sosa/
|
|
examples:
|
|
- value:
|
|
has_or_had_identifier: https://nde.nl/ontology/hc/zone/na-depot-a-standard
|
|
has_or_had_label: Standard Archive Storage Zone A
|
|
has_or_had_type: ARCHIVE_STANDARD
|
|
has_or_had_description: 'Climate-controlled archive storage meeting ISO 11799 requirements.
|
|
Paper-based collections from 1800-1950.
|
|
'
|
|
has_or_had_setpoint:
|
|
- setpoint_type: TEMPERATURE
|
|
setpoint_value: 18.0
|
|
setpoint_min: 16.0
|
|
setpoint_max: 20.0
|
|
setpoint_tolerance: 2.0
|
|
setpoint_unit: DEGREE_CELSIUS
|
|
iso_standard_reference: ISO 11799
|
|
- setpoint_type: RELATIVE_HUMIDITY
|
|
setpoint_value: 50.0
|
|
setpoint_min: 45.0
|
|
setpoint_max: 55.0
|
|
setpoint_tolerance: 5.0
|
|
setpoint_unit: PERCENT
|
|
max_light_lux: 50.0
|
|
environmental_requirement: https://nde.nl/ontology/hc/StandardArchiveEnvironment
|
|
monitoring_platform: Hanwell RadioLog monitoring system
|
|
part_of_facility: https://nde.nl/ontology/hc/storage/na-depot-a
|
|
- value:
|
|
has_or_had_identifier: https://nde.nl/ontology/hc/zone/ef-cold-vault
|
|
has_or_had_label: Cold Storage Vault - Film Archive
|
|
has_or_had_type: COLD_STORAGE
|
|
has_or_had_description: "Refrigerated vault for nitrate and acetate film negatives.\nMaintained at -5\xB0C, 30% RH per ISO 18911.\n"
|
|
has_or_had_setpoint:
|
|
- setpoint_type: TEMPERATURE
|
|
setpoint_value: -5.0
|
|
setpoint_min: -8.0
|
|
setpoint_max: -2.0
|
|
setpoint_tolerance: 3.0
|
|
setpoint_unit: DEGREE_CELSIUS
|
|
iso_standard_reference: ISO 18911
|
|
- setpoint_type: RELATIVE_HUMIDITY
|
|
setpoint_value: 30.0
|
|
setpoint_min: 25.0
|
|
setpoint_max: 35.0
|
|
setpoint_tolerance: 5.0
|
|
setpoint_unit: PERCENT
|
|
max_light_lux: 0.0
|
|
environmental_requirement: https://nde.nl/ontology/hc/ColdStorageEnvironment
|
|
part_of_facility: https://nde.nl/ontology/hc/storage/ef-main-depot
|
|
annotations:
|
|
specificity_score: 0.1
|
|
specificity_rationale: Generic utility class/slot created during migration
|
|
custodian_types: "['*']"
|